Select equipment
Data sheets of pressure-reducing desuperheating station, of stop valves, of regulating valves
- Stop Valves
- Gate Valves (Medium Parameters)
- Gate Valves (High Pressure)
- Check Valves
- Steam Traps
- Safety Valves 7с
- Pulse Valves 8с
- Pulse Valves 112
- Pulse Valves 586
- Main Safety Valves
- Regulating disk valves
- Regulating Rotary Valves 6c
- Regulating Needle Valves with lever actuation
- Regulating Needle Valves
- Throttle Control Valves
- Quick-Release Valves
- Butterfly Valves
- Double-Seat Regulating Valves 14с
1012-175-Э
Destignation | Dn, mm | Pn, MPa | ξ | Torque, N•m | n | D, mm | d, mm | L, mm | l, mm | A, mm | H, mm | DM, mm | Actuator type*** | Weight, kg | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
175 | 23,5* | 250 | 0,40 | 1150 | 22,5 | 235 | 182 | 650 | 217 | 977 | Г | 858** |
Условные обозначения
body – steel 20ГСЛ (GOST 108.961.03), steel 15ГС (GOST 108.030.113);
yoke – steel 25Л, steel 20ГСЛ (GOST 977);
cover – steel 20К (GOST 5520), steel 20ГСЛ (GOST 108.961.03);
valve spindle – steel 25Х1МФ (GOST 20072) with catalytic nitrogenization;
valve disk – steel 20 (GOST 1050) with building-up welding 04Х19Н9С2 (GOST 2246) or 25Х1МФ (GOST 20072) with catalytic nitrogenization;
valve seat – steel 20 (GOST 1050) with building-up welding 04Х19Н9С2 (GOST 2246).
Gate valves are manufactured in accordance with Technical Specification 3741-003-79315310-2007.

Gate valves are used for leak-free cutting off water or steam. These valves are used only for cutting off (opening) pipelines. Connection to pipeline – by welding. Gate valves are operated by means of handwheel, parallel shaft reducer or right-angle reducer, electric drive.

* working pressure, Рр ** without electric actuator *** ref. electric drives section